Executive findings
DAS has broad and strong evidence of identity in the exhibits it receives, not a census of Canada’s drug supply. Health Canada says DAS analyzes more than 100,000 suspected-drug samples annually, mainly for police and other government clients. The public data cannot establish what fraction of all Canadian police seizure events are submitted, because seizure events and laboratory samples are different units and no national linkage/denominator is published. Confidence A.
Routine work is mainly qualitative. DAS screens and confirms controlled substances. It can detect non-controlled active drugs and other compounds, but Health Canada says those compounds are not systematically tested or reported unless requested or relevant. The evidence supports “identified in a submitted exhibit,” not “complete chemical composition.” Confidence A.
Only a small, selected subset receives concentration testing. Health Canada states that approximately 1% of samples analyzed over the past 10 years receive quantification, for certain substances, under specific circumstances and based on police requests. Exact dates, unique-exhibit numerator, request categories and drug/province/agency rates are not public. Confidence A for the limitation; B for the approximate figure; D for the missing exact denominator details.
The verified 2024 numbers are aggregate means. The national table reports cocaine HCl 88.15% (n=732), crack cocaine 80.64% (n=42), methamphetamine HCl 78.52% (n=222), MDMA HCl 88.35% (n=31), heroin HCl 61.18% (n=11), fentanyl 15.05% (n=324), and carfentanil 0.54% (n=11). It does not publish the median, minimum, maximum, standard deviation, percentiles or sample-level values. Confidence A.
The public national table cannot answer the main distribution questions. It cannot show how many cocaine or methamphetamine exhibits exceed 90%, how many fentanyl exhibits are below 1%, or how many are nearly pure. A mean is compatible with radically different concentration distributions. Confidence A.
Multiple identified substances in one exhibit are common, especially for fentanyl. In Health Canada’s 2022 fentanyl analysis, 4.4% of fentanyl exhibits had no additional identified substance; 95.6% had one or more. This establishes co-detection, not deliberate adulteration, accidental contamination or synthesis impurity. Confidence A.
DAS can quantify multiple compounds, but routine practice is unresolved. DAS research describes methods that simultaneously quantify cocaine, heroin, methamphetamine and MDMA, and qNMR methods capable of quantifying controlled substances, diluents and adulterants in mixtures. The public record does not establish how often every major compound in a police exhibit is quantified or reported on a Certificate. Confidence B.
Selection bias is a supported methodological limitation, not evidence of manipulation. The selected/request-driven quantitative subset is not a probability sample. Health Canada expressly warns that its quantitative data are not comprehensive and are not intended to represent average purity in the broader supply. This supports the hypothesis that published means may be systematically affected by selection. It does not establish the direction or size of the effect, and no evidence of deliberate manipulation was located. Confidence A for non-random selection; D for direction/magnitude; E/unsupported for deliberate bias.
Method changes can mimic trends. Health Canada warns that expanded testing and greater analytical sensitivity can increase detections over time. Apparent growth in polysubstance findings must therefore be separated from true market change. No public adjustment variable or method-version time series was located. Confidence A.
The central evidentiary answer is conditional. Canadian authorities can support statements that many submitted exhibits contain specified detected substances and that selected quantitative results vary. Public DAS data alone do not support claims about the complete composition of all seizures, the full national concentration distribution, the intention behind co-occurrence, or the prevalence of “lacing” or “contamination” across the entire market. Confidence A.
What DAS knows, measures and publicly reports
| Question | What the evidence permits | What it does not permit | Confidence |
|---|---|---|---|
| Identity of controlled drugs in submitted exhibits | DAS uses screening and confirmation to identify controlled substances; one sample may contain several identified substances. | Does not establish that every seizure was submitted or every molecule was identified. | A |
| Non-controlled drugs, cutting agents and adulterants | May be detected and entered/reported when found through relevant testing; caffeine and other compounds appear in published co-occurrence work. | Health Canada says these are not systematically tested or reported; absence is not proof of absence. | A |
| Purity/concentration | Certain substances are quantified under specific circumstances; national mean and number of analyses are published by year/quarter and powder/tablet form. | No representative supply average, full distribution, province, agency, seizure size or selection reason. | A |
| Multiple substances | Same-sample co-identification can be measured and, in some methods, multiple compounds can be quantified. | Public data generally do not reveal the amount of each co-occurring compound or why it is present. | A/B |
| LIMS content | LIMS supports exhibit-level fentanyl and co-occurrence analyses and therefore records many controlled and non-controlled identifications. | No public proof that every detected peak/compound, trace, negative result or semi-quantitative result is entered. | B/D |
| Raw analytical files | Chromatography, mass-spectrometry and NMR techniques necessarily generate instrument output in relevant analyses. | Public record does not establish retention period, file format, linkage, routine preservation or disclosure status. | Likely; requires ATIP/disclosure |
| Certificate of Analyst | Health Canada says a Certificate is issued per sample; court examples show one or multiple substances may be listed. | No systematic certificate corpus showing how often concentration, methods, uncertainty or all co-detections are reported. | A/D |
Primary sources: DAS service page, Analyzed Drug Report, and data sources and limitations.
Compound classes: routine evidence ceiling
| Compound class | Routine qualitative status located | Routine LIMS recording established? | Public reporting status | Assessment |
|---|---|---|---|---|
| Controlled substances | Screened/confirmed as DAS’s primary mandate | Yes for reported identifications | Aggregate counts/trends | KNOWN — A |
| Precursor chemicals | DAS service mandate includes precursors and clandestine laboratories | Partial; exact fields/rules not public | Selected reports; no complete public extract | PARTIAL — B |
| Non-controlled active drugs | May be identified when testing finds them or they are requested/relevant | Many are demonstrably recorded | Not systematic | PARTIAL — A/B |
| Adulterants / cutting agents | Some identified; caffeine, phenacetin, dimethylsulphone and others appear in reports/cases | Many are demonstrably recorded | Incomplete and method-dependent | PARTIAL — A/B |
| Excipients | qNMR capability exists; operational screening/reporting rule not located | Unknown | No comprehensive public table | REQUIRES ATIP — D |
| Synthesis impurities/by-products | Health Canada referred to impurity profiling in an ATIP dispute | Unknown in routine LIMS/public stats | No comprehensive public table | REQUIRES ATIP — D |
| Metabolites | No routine seized-exhibit policy located | Unknown | No comprehensive public table | UNKNOWN — D |
| Novel psychoactive substances | DAS identifies and monitors new substances; capabilities evolve | Yes where identified/reported | Notifications and aggregate trends | KNOWN/PARTIAL — A |
“Detected” is method- and threshold-dependent. A more sensitive instrument or expanded target library can produce more identifications even if the underlying market does not change.
Police seizure submission: the denominator that is missing
Health Canada’s annual “more than 100,000” figure counts suspected-drug samples analyzed by DAS. A police seizure event may contain no submitted sample, one sample, several exhibits or several subsamples. The public platform cautions that multiple samples can originate from the same seizure and does not expose seizure-level identifiers, dates or quantities.
Accordingly:
- KNOWN: DAS analyzes approximately 100,000-plus submitted samples annually. A
- KNOWN: submission patterns reflect enforcement priorities, investigative needs and regional activity. A
- UNKNOWN: total Canadian drug-seizure events and the subset that generated at least one DAS sample. D
- NOT CALCULABLE: “percentage of all Canadian police seizures submitted to DAS” from the available DAS sample tables. A for the methodological conclusion.
- INVALID METHOD: dividing the number of DAS samples by a police seizure-event count, because numerator and denominator are not commensurate and repeated samples can come from one event. A.
Historical guidance reproduced in a 2017 Public Safety Canada report told police to make within-case selections where many similar exhibits existed and to cancel analysis after a guilty plea where possible. This offers an innocent administrative explanation—finite capacity and evidentiary necessity—for why laboratory samples are not a census. It is historical evidence; the current manual must be obtained before treating the exact rules as current. Public Safety Canada report. Confidence A for the historical document; D for current applicability.
What “approximately 1%” means—and does not mean
Health Canada’s limitation statement says approximately 1% of drug samples analyzed by DAS over the past 10 years receive quantification. It also says the work is for certain substances, under specific circumstances, and based on police requests. The public table separately reports a “number of quantitative analyses.”
| Element | Located answer | Status |
|---|---|---|
| Numerator | Samples receiving quantification, according to narrative text; public table counts quantitative analyses, which may be determinations | Exact unique-exhibit numerator unresolved |
| Denominator | All drug samples analyzed by DAS over the past 10 years | Exact inclusion rules unresolved |
| Time period | “Past 10 years” on the current page | Exact start/end date not stated |
| Unit | Narrative: samples; table: analyses | Possible unit mismatch; data dictionary required |
| By drug/year | Table gives analysis counts by drug/year/quarter | Does not state unique exhibits |
| By province/agency | Not in the located quantitative file | Unresolved |
| Selection | Police request and specific investigative circumstances | Established at high level; detailed codes/reasons absent |
Summing all published annual quantitative-analysis rows and dividing by national DAS sample counts gives the following diagnostic—not an exhibit-quantification rate:
| Year | Published quantitative determinations | National DAS samples | Determinations per 100 samples |
|---|---|---|---|
| 2019 | 1,867 | 99,341 | 1.879 |
| 2020 | 1,661 | 87,549 | 1.897 |
| 2021 | 1,524 | 96,556 | 1.578 |
| 2022 | 1,601 | 96,284 | 1.663 |
| 2023 | 2,055 | 95,296 | 2.156 |
| 2024 | 1,427 | 97,635 | 1.462 |
| 2025 | 1,356 | 96,499 | 1.405 |
| 2026 YTD | 498 | 45,214 | 1.101 |
These ratios exceed 1% in several years, but that is not proof Health Canada’s statement is wrong. Plausible explanations include several analyte determinations from one exhibit, a different rolling decade, table-coverage rules, repeated testing or a distinction between “samples” and “analyses.” This is a denominator/unit discrepancy requiring a data dictionary, not evidence of manipulation. Confidence A for the observed arithmetic; D for the explanation.
Verified quantitative concentration data
2024 national powder results
| Substance | Number of quantitative analyses | Mean concentration (% w/w) | Public median/min/max/SD/percentiles |
|---|---|---|---|
| Cocaine hydrochloride | 732 | 88.15 | Not published |
| Crack cocaine | 42 | 80.64 | Not published |
| Methamphetamine hydrochloride | 222 | 78.52 | Not published |
| MDMA hydrochloride | 31 | 88.35 | Not published |
| Heroin hydrochloride | 11 | 61.18 | Not published |
| Fentanyl | 324 | 15.05 | Not published |
| Carfentanil | 11 | 0.54 | Not published |
Source: Health Canada’s downloadable quantitative CSV, retrieved 2026-09-02. Reliability A. The counts are labelled analyses and have not been shown to equal unique exhibits.
National annual trend, powder means (% w/w)
Each cell is mean (number of analyses). 2026 is partial-year and should not be compared as a completed annual estimate.
| Year | Cocaine HCl | Crack cocaine | Meth HCl | MDMA HCl | Heroin HCl | Fentanyl | Carfentanil |
|---|---|---|---|---|---|---|---|
| 2019 | 73.19 (870) | 69.98 (61) | 87.17 (273) | 88.57 (7) | 49.87 (38) | 5.99 (495) | 0.36 (66) |
| 2020 | 73.59 (724) | 60.51 (71) | 87.71 (115) | 86.31 (13) | 48.27 (11) | 10.55 (632) | 2.96 (35) |
| 2021 | 77.65 (710) | 63.63 (94) | 95.16 (130) | 86.67 (6) | 37.72 (14) | 12.75 (494) | 0.45 (63) |
| 2022 | 81.60 (680) | 73.10 (71) | 80.32 (163) | 64.88 (16) | 57.46 (24) | 13.78 (519) | 0.50 (46) |
| 2023 | 85.78 (795) | 80.79 (75) | 78.79 (249) | 87.17 (94) | 73.28 (18) | 13.87 (625) | 0.68 (40) |
| 2024 | 88.15 (732) | 80.64 (42) | 78.52 (222) | 88.35 (31) | 61.18 (11) | 15.05 (324) | 0.54 (11) |
| 2025 | 87.33 (712) | 73.77 (52) | 88.72 (129) | 68.55 (44) | 72.91 (11) | 9.43 (314) | 0.78 (22) |
| 2026 YTD | 87.23 (264) | 81.29 (35) | 76.31 (58) | 78.00 (13) | 8.00 (2) | 17.19 (49) | 22.22 (33) |
The 2026 YTD carfentanil mean of 22.22% is far above previous annual means. It may reflect a small request-driven cluster, outliers, a market change, a method/code/form change or another factor. It should be flagged, not narrated as a settled national trend, until row-level observations and method/selection metadata are obtained. Observed figure A; explanation D.
Requested drugs absent from the located quantitative CSV
No rows were located for hydromorphone, oxycodone, benzodiazepines or xylazine in the current national quantitative CSV. This means only that the located public table contains no such row; it is not evidence that DAS lacks a method or never quantified those substances. Benzodiazepine and xylazine public products provide identification/co-occurrence counts, not concentration distributions. Confidence A for file contents; D for operational capability/frequency.
Tablets versus powders
Powder values are % w/w; tablet values are
mg/unit. They are not interchangeable. In 2024, the table
reported fentanyl tablets at 3.29 mg/unit (n=7), MDMA tablets at 168.0
mg/unit (n=10), and methamphetamine tablets at 13.73 mg/unit (n=16). A
tablet’s mg/unit result cannot be converted to percent without unit mass
and formulation information. Confidence A.
Salt/base form caution
The public codes include HCL and FB, but
the displayed labels do not provide a complete codebook or conversion
rules. The normalized dataset retains the original code and decodes
“hydrochloride” only where the public label does so. It does not
silently infer that every FB value is a reported free-base
equivalent. Confidence A for the data limitation.
The distribution question
The located public quantitative data are insufficient to calculate
any requested concentration band—<1%, 1–5%,
5–10%, 10–25%, 25–50%,
50–75%, 75–90%, >90% or
>95%—for any drug. A mean and sample count do not
identify individual values.
Two fentanyl datasets can each have a 15% mean:
- Distribution A: 100 exhibits, each exactly 15%.
- Distribution B: 80 exhibits at 5% and 20 exhibits at 55%: ((80×5 + 20×55)/100 = 15%).
Distribution A has no exhibit below 10% or above 50%; Distribution B has 80 below 10% and 20 above 50%. The same published mean supports both.
Likewise, a cocaine mean of 88.15% is compatible with all samples at 88.15%, or with half at 76.30% and half at 100%. The first distribution has no samples above 90%; the second has half above 90%.
Therefore:
- “The selected 2024 cocaine-HCl analyses averaged 88.15%” is supported.
- “Most seized cocaine was nearly pure” is not established by the mean.
- “X% of cocaine was above 90%” is not calculable.
- A seizure-weighted market estimate would additionally require exhibit/seizure weights and a defensible sampling design.
A 2020 peer-reviewed DAS community drug-checking project reported fentanyl concentrations from 1% to 91% w/w, with median 8% in its special-project sample. That establishes measured variability in that scoped project, not the national police-exhibit distribution. Study. Confidence B; generalization ceiling explicit.
Polysubstance and co-occurrence findings
Fentanyl
Health Canada analyzed 77,141 fentanyl exhibits from 2012–2022. In 2022:
| Additional identified substances | Share of fentanyl exhibits |
|---|---|
| None | 4.4% |
| 1 | 27.0% |
| 2 | 33.0% |
| 3 | 20.7% |
| 4 | 8.9% |
| 5 | 3.4% |
| 6 | 1.7% |
| 7 or more | 0.8% |
Thus 95.6% had at least one additional identified substance and 69.0% had two or more. Among 2022 fentanyl exhibits, the share with two or more additional substances was reported as 53% in British Columbia, 62% in Alberta and 77% in Ontario. Differences may reflect regional supply, forms, submitting agencies, enforcement patterns, target lists, method sensitivity or combinations of these. Confidence A for the reported figures; D for cause.
Top reported fentanyl co-occurrences over 2012–2022:
| Compound | Share of fentanyl exhibits |
|---|---|
| Caffeine | 84.8% |
| Dimethylsulphone | 20.6% |
| Diacetylmorphine (heroin) | 16.7% |
| Etizolam | 10.5% |
| Methamphetamine | 7.1% |
| Cocaine | 5.8% |
| Phenacetin | 4.3% |
| Carfentanil | 4.1% |
| Flualprazolam | 3.6% |
| Diphenhydramine | 3.0% |
Source: Health Canada fentanyl spotlight. The report groups diverse non-controlled substances together; these percentages do not provide concentration or causal classification. Reliability A.
Xylazine
Among 2,324 xylazine exhibits from 2012–2022, 23 (1.0%) contained no other identified substance; 93% co-occurred with fentanyl. Health Canada reported the following additional-substance counts: none 1.0%, one 1.5%, two 26.4%, three 29.9%, four 22.8%, five 9.5%, six 5.2%, seven 2.4%, eight 0.8%, nine 0.4%, and ten 0.1%. Xylazine spotlight. Confidence A.
The newer 2021–2026 Q1 product reports fentanyl in 74% of xylazine samples, while 28.6% of medetomidine samples also contained xylazine. Differences in date range, denominator and substance definitions must be preserved. Open Government dataset page. Confidence A.
Benzodiazepines
For benzodiazepine samples in the 2017–2026 Q1 product, the leading controlled-substance co-occurrences were fentanyl 49.6%, para-fluorofentanyl 14.8%, methylfentanyl 4.3%, methamphetamine 3.7% and carfentanil 2.7%. In 2025, 28.1% of fentanyl/analogue samples reportedly contained at least one benzodiazepine. These are identities, not concentrations. Open Government dataset page. Confidence A.
Heroin, methamphetamine, cocaine, MDMA and counterfeit tablets
A 2020 CCSA technical report used a DAS-provided sample-level extract covering April 2018–August 2019. The extract contained 167,630 unique DAS samples and listed reported substances by sample but not their quantities, buyer expectation, local context or seizure circumstances.
| Index category | Samples | “Only” index drug/class | Any reported other substance | Selected co-occurrence finding |
|---|---|---|---|---|
| Opioid-containing | 23,338 | 31% opioids only | 69% included a non-opioid | Caffeine 59%; dimethylsulphone 13% |
| Methamphetamine | 37,625 | 54% only the specific stimulant | 46% had something else under report categories | Fentanyl/analogue 3% (n=1,021) |
| Cocaine | 38,429 | 71% cocaine only | 29% had something else | Fentanyl/analogue 2% (n=931) |
| MDMA | 2,777 | 83% MDMA only | 17% had something else | Fentanyl/analogue 1% (n=33) |
Source: CCSA technical report. Reliability B: government-funded, DAS-supplied data, transparent limitations; secondary classification. The report does not provide a separate full one/two/three/four/five-plus breakdown for each requested drug, and it cannot distinguish dominant ingredient from trace identification.
No equivalent public count distribution was located for heroin, carfentanil or counterfeit tablets. The announced platform “Co-occurrence Patterns” feature remained marked “coming soon” on the evidence cut-off date. This is a public-data gap, not proof DAS lacks the underlying associations.
Required language discipline
Every same-sample co-occurrence row in this module is classified as:
DETECTED TOGETHER — causal mechanism UNKNOWN
Do not automatically translate it into:
- DELIBERATELY MIXED — requires formulation, communications, admission, manufacturing evidence or another causal basis;
- ACCIDENTAL CONTAMINATION — requires a defensible cross-contamination analysis, process evidence or trace-context interpretation;
- SYNTHESIS IMPURITY — requires chemical-route/impurity profiling and appropriate expert interpretation;
- COUNTERFEIT SUBSTITUTION — requires reliable appearance/marking/expected-content evidence; or
- LACED — requires a defined meaning and evidence about expectation or addition, not mere co-detection.
“Contamination” is not a neutral synonym for “a second detected analyte.” Analytically it should identify a proposed mechanism, contextual threshold and evidence basis.
Quantification of mixtures
DAS research provides two important capability findings:
- A validated UPLC triple-quadrupole method can quantify cocaine, heroin, methamphetamine and MDMA in one exhibit analysis.
- NMRquant was designed to identify and quantify compounds in mixed forensic samples and can quantify controlled substances, diluents and adulterants in a single analysis.
Sources: Health Canada research abstracts, 2020–2021, 2021–2022 abstracts, and the NMRquant methods paper.
These sources establish capability, not the following operational facts:
- that every active drug in every mixture is quantified;
- that every major diluent is quantified;
- that police routinely request complete percentage composition;
- that the final Certificate lists every quantitative result;
- that the public national table preserves within-exhibit multi-analyte results; or
- that semi-quantitative instrument response is retained or reportable.
No verified public Certificate stating a full composition such as “fentanyl X%, bromazolam Y%, caffeine Z%” was located. The correct status is REQUIRES ATIP/DISCLOSURE, not “DAS does not possess the data.”
Why high cocaine/methamphetamine means can coexist with much lower fentanyl means
The figures are chemically and commercially plausible because end-market fentanyl mixtures can deliver pharmacological effect at far lower mass fraction than cocaine or methamphetamine products, while salts, diluents and tablet formulations differ. But the public table cannot apportion the observed difference among:
- ordinary market formulation and potency;
- drug-specific quantitative methods or reporting equivalents;
- different request patterns and case types;
- seizure size or trafficking/import investigations;
- laboratory capacity and service policies;
- regional market composition; and
- time-varying analytical sensitivity.
Thus “selected fentanyl analyses had a much lower mean mass fraction” is established. “The fentanyl supply is more diluted because of deliberate adulteration” is not established from the mean alone. Confidence A for contrast; D for causal decomposition.
Selection-bias assessment
Hypothesis
Published mean DAS concentration figures may be systematically biased because samples selected for quantitative testing are not a random sample of the illicit drug supply.
Classification: SUPPORTED, with limits.
Evidence supporting the classification:
- Health Canada says quantitation is done on a very small subset, for certain substances, under specific circumstances and based on police requests.
- It says submission patterns reflect enforcement priorities and investigative needs.
- It expressly says the quantitative data are not comprehensive and not intended to reflect average purity in the broader supply.
- Historical client guidance required a well-founded, supervisor-supported quantitative request and encouraged selection among similar exhibits.
What remains unresolved:
- whether selection raises or lowers the mean for a given drug;
- whether large seizures, trafficking cases, imports, clandestine laboratories, organized crime, sentencing issues or unusual potency are overrepresented;
- whether police, Crown, DAS initiatives or research projects dominate the quantitative subset;
- how selection changed by year, province, laboratory and drug; and
- whether more than one quantitative determination can come from the same exhibit.
Competing explanations that do not imply wrongdoing:
| Explanation | Present evidence | Status |
|---|---|---|
| Evidentiary necessity in a particular prosecution | Police-request basis and historical justification rule | Supported generally |
| Resource/capacity allocation | Very small subset and service-priority design | Plausible; not quantified |
| Method availability by analyte/form | Table covers selected substances/forms | Supported generally |
| Representative surveillance sampling | Health Canada disclaims representativeness | Unsupported for public table |
| Focus on large/organized-crime/superlab seizures | Institution described security/organized-crime context in OIC case | Plausible for some work; quantitative overrepresentation untested |
| Focus on unusually potent samples | No public selection field | Unresolved |
| Deliberate manipulation of published means | No evidence located | Unsupported/speculative |
No causal or accusatory wording should exceed these limits.
Who may submit samples
The Controlled Drugs and Substances Act distinguishes statutory submission to a designated analyst from DAS’s operational client categories. Section 45 permits a peace officer, inspector or prescribed person to submit a substance or sample taken by them. Health Canada separately lists law enforcement, CBSA, CSC and criminal justice representatives as clients.
| Submitter | Classification | Evidentiary basis / limit |
|---|---|---|
| RCMP | ROUTINE ACCESS | Peace officers; named law-enforcement client |
| Municipal police | ROUTINE ACCESS | Peace officers; routine client |
| Provincial police | ROUTINE ACCESS | Peace officers; routine client |
| CBSA | ROUTINE ACCESS | Explicit Health Canada client |
| Correctional Service Canada | ROUTINE ACCESS | Explicit client for institutional exhibits |
| Other federal agencies | LIMITED ACCESS | Depends on mandate and statutory/person class |
| Crown / criminal justice representatives | LIMITED ACCESS | Operational client/liaison described; direct s.45 submitter basis not established |
| Coroners / medical examiners | UNKNOWN | No routine DAS route located |
| Provincial health authorities | SPECIAL PROJECT ACCESS | Collaborations documented; not general routine entitlement |
| Supervised consumption sites | SPECIAL PROJECT ACCESS | Project testing documented |
| Drug-checking programs | SPECIAL PROJECT ACCESS | DAS-supported projects documented |
| Festivals/event drug checking | SPECIAL PROJECT ACCESS | Health Canada evaluation describes activity |
| Academic researchers | SPECIAL PROJECT ACCESS | Research collaboration possible; direct routine route not established |
| Ordinary public | NO APPARENT ACCESS | Not a named client or established s.45 class |
Authorities: CDSA s.45, DAS service page, and CDSS evaluation. Confidence A for statutory text and named clients; B/D for limited and special categories.
Public-health submissions could affect aggregate patterns if included, because their selection mechanisms differ from police exhibits. The current public quantitative file has no submitter/project field, so material effect cannot be measured. Plausible but unresolved — D.
Certificates of Analyst and underlying records
Health Canada says a Certificate of Analyst is produced for each analyzed sample. Under CDSA ss.51–52, an analyst’s certificate/report may be admissible as proof of its statements, subject to statutory procedure; Criminal Code s.729 addresses notice and provision of a copy when such a certificate/report is used.
Located examples
| Example | Substance statements located | Concentration shown in accessible source? | Evidentiary limit |
|---|---|---|---|
| Public 2022 Gatineau scan | Cocaine | No | Purported certificate hosted by a user; authenticity/provenance unverified (D) |
| R. v. Auclair, 2023 ONSC 6590 | Fentanyl and caffeine | Not stated in reasons | Judicial reasons summarize certificate; court discussed why quantitation is not commonly requested (A) |
| R. v. Folk, 2025 ONSC 4243 | Cocaine, fentanyl, phenacetin and caffeine | Not stated in reasons | Judicial reasons show multi-compound identity reporting, not complete composition (A) |
Links: Auclair, Folk, and unverified scan.
Fields visible in the unverified scan include laboratory/location, analyst, source police service, delivery/possession date, seal/file identifiers, a sealed-package statement, sampling statement and controlled-substance/schedule finding. It did not visibly report concentration, method, uncertainty or a complete composition. One scan cannot define all certificate formats.
Disclosure ceiling
- Normally supported: if the prosecution relies on a certificate/report, statutory notice and a copy are required. A.
- Not established as automatic: bench notes, chromatograms, spectra, instrument raw files, validation packages, LIMS audit records, uncertainty calculations and full chain-of-custody documentation. D.
- Practical status: those materials should be specifically identified in disclosure requests where relevant; legal entitlement and production may be litigated case by case. Requires legal review.
- Retention: no verified DAS-specific public retention period was located. Health Canada’s Info Source inventory identifies a DAS Quality Manual but does not answer the raw-file retention question. D / REQUIRES ATIP.
Current and historical manuals, SOPs and methods inventory
| Record | Located status | Date/version | Access note |
|---|---|---|---|
| Client Manual for Exhibit Submission & Analysis Requests | Current document exists | Current | Health Canada says available on request |
| Client Manual | Catalogue record | September 2013, 54 pages, ISBN 978-1-100-22552-4 | PDF removed from publications.gc.ca at department request; original collection URL no longer available |
| Client Manual | Catalogue record | September 2016, 43 pages, ISBN 978-0-660-05417-9 | PDF removed at department request |
| Client Manual | Catalogue record | March 2019, 43 pages, ISBN 978-0-660-29608-1 | PDF removed at department request |
| Training Manual | Catalogue/current service reference | 2013 catalogue; current version available on request | Full historical/current text not retrieved |
| Clandestine Laboratory Investigation: Guidelines for Law Enforcement Agencies | Current document exists | Current | Available on request |
| Client Portal User Manual | Current document exists | Current | Available on request |
| DAS Quality Manual | Official holdings inventory lists it | Current/historical versions unknown | Requires ATIP; some operational content may be exempt |
| SOP master index | Not located publicly | Unknown | ATIP target |
| Method-validation publications | Several located | 2020–2022 abstracts/papers | Capability evidence, not complete SOP set |
Catalogue links: 2013, 2016, 2019. The fact that PDFs were removed is documented; motive beyond the catalogue notation is unknown. It must not be rewritten as “concealment.” Confidence A for catalogue status; E for unproven motive.
Public access inventory
| Product | Public? | Observation level | Main limit |
|---|---|---|---|
| Analyzed Drug Report | Yes | Aggregated counts/trends and national quant means | No anonymous exhibit records |
| Direct downloadable CSVs | Yes | Aggregated substance/year/quarter/province tables | No documented exhibit ID or selection reason |
| Drug Trends | Yes | Aggregated time trends | Submission/testing changes affect inference |
| Drug Notification Map | Yes | Selected alerts by region/time | Notification criteria; not a prevalence map |
| Purity/quantitative table | Yes | National mean/count by selected drug, year/quarter and form | No distribution/province/agency |
| Co-occurrence spotlight reports | Yes | Aggregate same-sample identifications | No quantities/intent/cause |
| “Co-occurrence Patterns” platform feature | Not yet on cut-off date | Announced | Marked coming soon |
| Scientific publications/method papers | Yes, selected | Methods/special projects | Not a full operational-method registry |
| Searchable exhibit-level DAS database | Not located | — | Unknown whether planned |
| Documented public API | Not located | — | Direct CSV endpoints are not an exhibit-level API |
Platform: Analyzed Drug Report, Drug Trends, Drug Notification Map, publications.
Contradictions and discrepancies register
- One-percent narrative versus 1.4–2.2 determinations per 100 samples. Possible unit/time/coverage mismatch; unresolved until Health Canada supplies the data dictionary. Do not call this falsification. A/D.
- “All substances” wording in the 2020 CCSA report versus current non-controlled reporting limitation. “All” may mean all reported identifications in the supplied extract, not complete chemical composition; methods/scope may also have changed. B/D.
- 2026 YTD carfentanil mean. 22.22% (n=33) is discontinuous with prior annual means. Small selected subset and other innocent explanations remain open. A/D.
- Current manuals available on request versus removed historical PDFs. This establishes an access barrier/history, not intent. A/E.
- Technical multi-analyte capability versus sparse public composition reporting. Capability does not imply routine performance, LIMS retention or certificate disclosure. B/D.
Alternative explanations matrix
| Observation | Competing explanations that remain live |
|---|---|
| Increasing number of co-detected substances | Market change; target-list expansion; sensitivity improvement; changed submission mix; changed reporting rule |
| Fentanyl mean lower than stimulant means | Pharmacological potency/formulation; market practice; salt/base conventions; selection by case/drug; method/reporting differences |
| Provincial co-occurrence differences | Genuine regional supply; enforcement priorities; public-health submissions; forms; method/lab changes; small cells |
| High annual mean | Many consistently high results; bimodal distribution; a few high outliers; case clustering; seizure-size selection |
| Compound appears in same sample | Intentional formulation; accidental mixing; synthesis carryover; cross-contamination; trace analytical carryover; unknown |
| Non-controlled compound absent from public data | Truly absent; not targeted; below threshold; detected but not systematically recorded/reported; excluded from publication |
| Quantitative result requested | Evidentiary need; policy/charge requirement; large seizure; special research; unusual potency; routine method opportunity |
Unresolved questions and evidence needed
The 40 staged question cards are in
data/question_cards.jsonl. The highest-value unresolved
issues are:
- the national seizure-event denominator and sample-to-seizure linkage;
- exact numerator/unit/time window behind “approximately 1%”;
- row-level concentration results needed for bands, medians, ranges and geographic comparisons;
- reason/requester/case variables needed to measure selection bias;
- a LIMS data dictionary and which non-controlled identifications are compulsory, optional or omitted;
- multi-analyte quantitative results within one exhibit;
- method-version, LOD/LOQ and reporting-threshold history;
- raw-file/bench-note/LIMS retention schedules;
- a representative corpus of Certificates and disclosure inventories; and
- separate flags for police, border, corrections, public-health and research submissions.
The accompanying ATIP draft requests these records in anonymized machine-readable form and asks for field-level severance instead of case identifiers.
Suggested court-record searches
- Search CanLII and provincial repositories for combinations of
"Certificate of Analyst" AND (purity OR concentration OR quantitative OR chromatogram OR spectrum OR LIMS OR bench notes). - Search for
fentanyl AND caffeine AND "Certificate of Analyst",carfentanil AND concentration, andbromazolam AND certificate. - Prioritize cases where purity affected sentencing, trafficking value, possession for the purpose, expert opinion, representative sampling or hotspot arguments.
- Obtain docket exhibits/transcripts for Auclair and Folk; judicial summaries alone are not certificate images.
- Seek disclosure indices before full files to identify whether bench notes, spectra, validation and chain-of-custody records were produced.
- Record certificate version, lab, date, field presence/absence and whether the court relied on identity, concentration or both.
- Do not treat a judgment’s summary of expert evidence as the
laboratory record itself; preserve the layer
court summary of certificate.
ATIP and disclosure strategy
The proposed request asks for a stable anonymous exhibit ID, every detected/reported substance, all quantitative values/units, methods, selection/request fields, geography, form/weight, LOD/LOQ, uncertainty, reanalysis linkage and project type, while expressly inviting removal of police file numbers and personal identifiers.
It also seeks manuals, SOP indexes, the Quality Manual, LIMS codebooks, retention schedules, quantitation-selection policies and guidance on which adulterants/excipients are recorded.
The 2026 Information Commissioner decision is important context. In Health Canada (Re), 2026 OIC 14, Health Canada had withheld DAS-related records under law-enforcement, advice and testing-procedure exemptions. The Commissioner found the complaint well founded, held that Health Canada had not justified many redactions or full-page withholding, and ordered substantial severed disclosure. The decision also accepted that some testing details could properly remain exempt. It supports targeted, severable requests; it does not establish that an anonymized LIMS dataset has already been released. Confidence A.
Cross-links for Evidence Deck review
These are flags, not automatic duplicates:
| Finding | Target |
|---|---|
| Selected fentanyl means and distribution limits | Fentanyl Science Deck |
| Fentanyl 95.6% additional-substance finding | Fentanyl Science Deck |
| “Detected together” language guardrail | Fentanyl Language Deck |
| Certificate scope and disclosure | Fentanyl Legal Deck |
| Request-driven selection and bias | Law Enforcement Deck |
| Public-health/festival projects | Public Institutions Deck |
| Multi-analyte capability and method evolution | Research & Science Deck |
| Co-detection versus lacing/contamination | Contaminated Drug Supply / Laced-with-Fentanyl registry |
Before import, recover ED-P25QE and ED-CSM-001, deduplicate by claim/source family, preserve existing IDs and append new evidence-assessment versions. No public card or adverse inference should be created automatically.
Source inventory and reliability
The machine-readable inventory contains 27 sources in
data/sources.jsonl, with publication/access dates, URLs,
local-copy paths where available, scope notes and A–E reliability
ratings.
Source families include:
- primary Health Canada service, methodology, dashboard, CSV and spotlight records (A);
- statutes and the OIC final report (A);
- official federal catalogue/manual records and Public Safety report (A);
- peer-reviewed DAS methods/special-project studies (B for operational inference because study samples and routine practice differ);
- CCSA’s DAS-supplied co-occurrence analysis (B); and
- a public user-uploaded certificate scan (D, illustrative only).
No search-engine snippet is treated as evidence. No inaccessible historical manual is treated as if its contents were reviewed. “Not located publicly” is not converted into “does not exist” or “is concealed.”
Final answer to the central question
When Canadian authorities describe the illicit supply as variable or containing multiple drugs, DAS provides strong evidence for identified substances in the submitted exhibits it actually tested, and special studies demonstrate large concentration variability in scoped samples. For fentanyl, the 2022 same-exhibit evidence strongly supports widespread co-occurrence with at least one additional identified substance.
However, the routine public record is primarily qualitative; non-controlled compounds are not systematically tested/reported; concentration testing is performed on a small, request-driven subset; and the public concentration table provides means rather than distributions. Consequently, public DAS data alone cannot establish the proportion of the entire illicit supply that is dilute, nearly pure, deliberately “laced,” accidentally contaminated or unusually potent. Nor can it determine how selection affects a drug’s published mean.
The evidence therefore permits four bounded statements:
- Identity: many submitted exhibits contain the substances DAS reports identifying. A.
- Co-occurrence: many fentanyl and xylazine exhibits contain additional identified substances. A.
- Selected concentration: specified, requested quantitative analyses have the reported national means and show change over time. A.
- Population/causal inference: full market distributions, intentional lacing, mechanism of contamination and selection-bias magnitude remain unresolved without anonymous row-level LIMS/quantitative records, selection fields and method history. D / REQUIRES ATIP OR DISCLOSURE.
That boundary—not a claim of wrongdoing—is the module’s principal finding.
Artifact guide
data/quantitative_concentration.csv— normalized 2019–2026 public mean/count rows, preserving codes, form and unitsdata/quantitative_coverage.csv— diagnostic determination/sample ratios with unit warningdata/requested_substance_coverage.csv— coverage status for requested drugsdata/cooccurrence.csv— fentanyl, xylazine and benzodiazepine co-occurrence rows with causal guardsdata/findings.jsonl— 36 confidence-rated findingsdata/question_cards.jsonl— 40 staged Evidence Deck cardsdata/sources.jsonl— 27-source inventorydata/submitter_access_matrix.csv— legal/operational access classificationsdata/certificate_examples.csv— located examples and limitsdata/contradictions.csv— discrepancy register with innocent explanationsdata/retrieval_tasks.jsonl— ATIP, disclosure and court-search queuedata/crosslinks.jsonl— private cross-link flagshealth_canada_das_overlay.sqlite— restorable standalone overlayintegration_receipt.json— baseline/integration/publication status and QC