Health Canada DAS — What Is Actually in the Drugs?

Original report dated September 2, 2026

Historical research module using the evidence available on September 2, 2026. The published concentration figures cover the selected samples that were quantified.

The original authoring status is preserved below. The archive includes the report text. The unverified user-uploaded certificate URL is omitted because the original document may contain case identifiers. The accompanying access-request draft and working files are referenced by their original labels. See the sampling and laboratory results analysis.

Evidence Deck module: ED-DAS-001
Status: Private investigation overlay; human review required; publication not authorized
Evidence cut-off / access date: 2026-09-02
Integration state: The authoritative Evidence Deck database, ED-P25QE package and ED-CSM-001 package were not supplied. This module therefore stages append-only records and cross-links but does not claim to have modified the canonical database.

Executive findings

  1. DAS has broad and strong evidence of identity in the exhibits it receives, not a census of Canada’s drug supply. Health Canada says DAS analyzes more than 100,000 suspected-drug samples annually, mainly for police and other government clients. The public data cannot establish what fraction of all Canadian police seizure events are submitted, because seizure events and laboratory samples are different units and no national linkage/denominator is published. Confidence A.

  2. Routine work is mainly qualitative. DAS screens and confirms controlled substances. It can detect non-controlled active drugs and other compounds, but Health Canada says those compounds are not systematically tested or reported unless requested or relevant. The evidence supports “identified in a submitted exhibit,” not “complete chemical composition.” Confidence A.

  3. Only a small, selected subset receives concentration testing. Health Canada states that approximately 1% of samples analyzed over the past 10 years receive quantification, for certain substances, under specific circumstances and based on police requests. Exact dates, unique-exhibit numerator, request categories and drug/province/agency rates are not public. Confidence A for the limitation; B for the approximate figure; D for the missing exact denominator details.

  4. The verified 2024 numbers are aggregate means. The national table reports cocaine HCl 88.15% (n=732), crack cocaine 80.64% (n=42), methamphetamine HCl 78.52% (n=222), MDMA HCl 88.35% (n=31), heroin HCl 61.18% (n=11), fentanyl 15.05% (n=324), and carfentanil 0.54% (n=11). It does not publish the median, minimum, maximum, standard deviation, percentiles or sample-level values. Confidence A.

  5. The public national table cannot answer the main distribution questions. It cannot show how many cocaine or methamphetamine exhibits exceed 90%, how many fentanyl exhibits are below 1%, or how many are nearly pure. A mean is compatible with radically different concentration distributions. Confidence A.

  6. Multiple identified substances in one exhibit are common, especially for fentanyl. In Health Canada’s 2022 fentanyl analysis, 4.4% of fentanyl exhibits had no additional identified substance; 95.6% had one or more. This establishes co-detection, not deliberate adulteration, accidental contamination or synthesis impurity. Confidence A.

  7. DAS can quantify multiple compounds, but routine practice is unresolved. DAS research describes methods that simultaneously quantify cocaine, heroin, methamphetamine and MDMA, and qNMR methods capable of quantifying controlled substances, diluents and adulterants in mixtures. The public record does not establish how often every major compound in a police exhibit is quantified or reported on a Certificate. Confidence B.

  8. Selection bias is a supported methodological limitation, not evidence of manipulation. The selected/request-driven quantitative subset is not a probability sample. Health Canada expressly warns that its quantitative data are not comprehensive and are not intended to represent average purity in the broader supply. This supports the hypothesis that published means may be systematically affected by selection. It does not establish the direction or size of the effect, and no evidence of deliberate manipulation was located. Confidence A for non-random selection; D for direction/magnitude; E/unsupported for deliberate bias.

  9. Method changes can mimic trends. Health Canada warns that expanded testing and greater analytical sensitivity can increase detections over time. Apparent growth in polysubstance findings must therefore be separated from true market change. No public adjustment variable or method-version time series was located. Confidence A.

  10. The central evidentiary answer is conditional. Canadian authorities can support statements that many submitted exhibits contain specified detected substances and that selected quantitative results vary. Public DAS data alone do not support claims about the complete composition of all seizures, the full national concentration distribution, the intention behind co-occurrence, or the prevalence of “lacing” or “contamination” across the entire market. Confidence A.

What DAS knows, measures and publicly reports

Question What the evidence permits What it does not permit Confidence
Identity of controlled drugs in submitted exhibits DAS uses screening and confirmation to identify controlled substances; one sample may contain several identified substances. Does not establish that every seizure was submitted or every molecule was identified. A
Non-controlled drugs, cutting agents and adulterants May be detected and entered/reported when found through relevant testing; caffeine and other compounds appear in published co-occurrence work. Health Canada says these are not systematically tested or reported; absence is not proof of absence. A
Purity/concentration Certain substances are quantified under specific circumstances; national mean and number of analyses are published by year/quarter and powder/tablet form. No representative supply average, full distribution, province, agency, seizure size or selection reason. A
Multiple substances Same-sample co-identification can be measured and, in some methods, multiple compounds can be quantified. Public data generally do not reveal the amount of each co-occurring compound or why it is present. A/B
LIMS content LIMS supports exhibit-level fentanyl and co-occurrence analyses and therefore records many controlled and non-controlled identifications. No public proof that every detected peak/compound, trace, negative result or semi-quantitative result is entered. B/D
Raw analytical files Chromatography, mass-spectrometry and NMR techniques necessarily generate instrument output in relevant analyses. Public record does not establish retention period, file format, linkage, routine preservation or disclosure status. Likely; requires ATIP/disclosure
Certificate of Analyst Health Canada says a Certificate is issued per sample; court examples show one or multiple substances may be listed. No systematic certificate corpus showing how often concentration, methods, uncertainty or all co-detections are reported. A/D

Primary sources: DAS service page, Analyzed Drug Report, and data sources and limitations.

Compound classes: routine evidence ceiling

Compound class Routine qualitative status located Routine LIMS recording established? Public reporting status Assessment
Controlled substances Screened/confirmed as DAS’s primary mandate Yes for reported identifications Aggregate counts/trends KNOWN — A
Precursor chemicals DAS service mandate includes precursors and clandestine laboratories Partial; exact fields/rules not public Selected reports; no complete public extract PARTIAL — B
Non-controlled active drugs May be identified when testing finds them or they are requested/relevant Many are demonstrably recorded Not systematic PARTIAL — A/B
Adulterants / cutting agents Some identified; caffeine, phenacetin, dimethylsulphone and others appear in reports/cases Many are demonstrably recorded Incomplete and method-dependent PARTIAL — A/B
Excipients qNMR capability exists; operational screening/reporting rule not located Unknown No comprehensive public table REQUIRES ATIP — D
Synthesis impurities/by-products Health Canada referred to impurity profiling in an ATIP dispute Unknown in routine LIMS/public stats No comprehensive public table REQUIRES ATIP — D
Metabolites No routine seized-exhibit policy located Unknown No comprehensive public table UNKNOWN — D
Novel psychoactive substances DAS identifies and monitors new substances; capabilities evolve Yes where identified/reported Notifications and aggregate trends KNOWN/PARTIAL — A

“Detected” is method- and threshold-dependent. A more sensitive instrument or expanded target library can produce more identifications even if the underlying market does not change.

Police seizure submission: the denominator that is missing

Health Canada’s annual “more than 100,000” figure counts suspected-drug samples analyzed by DAS. A police seizure event may contain no submitted sample, one sample, several exhibits or several subsamples. The public platform cautions that multiple samples can originate from the same seizure and does not expose seizure-level identifiers, dates or quantities.

Accordingly:

Historical guidance reproduced in a 2017 Public Safety Canada report told police to make within-case selections where many similar exhibits existed and to cancel analysis after a guilty plea where possible. This offers an innocent administrative explanation—finite capacity and evidentiary necessity—for why laboratory samples are not a census. It is historical evidence; the current manual must be obtained before treating the exact rules as current. Public Safety Canada report. Confidence A for the historical document; D for current applicability.

What “approximately 1%” means—and does not mean

Health Canada’s limitation statement says approximately 1% of drug samples analyzed by DAS over the past 10 years receive quantification. It also says the work is for certain substances, under specific circumstances, and based on police requests. The public table separately reports a “number of quantitative analyses.”

Element Located answer Status
Numerator Samples receiving quantification, according to narrative text; public table counts quantitative analyses, which may be determinations Exact unique-exhibit numerator unresolved
Denominator All drug samples analyzed by DAS over the past 10 years Exact inclusion rules unresolved
Time period “Past 10 years” on the current page Exact start/end date not stated
Unit Narrative: samples; table: analyses Possible unit mismatch; data dictionary required
By drug/year Table gives analysis counts by drug/year/quarter Does not state unique exhibits
By province/agency Not in the located quantitative file Unresolved
Selection Police request and specific investigative circumstances Established at high level; detailed codes/reasons absent

Summing all published annual quantitative-analysis rows and dividing by national DAS sample counts gives the following diagnostic—not an exhibit-quantification rate:

Year Published quantitative determinations National DAS samples Determinations per 100 samples
2019 1,867 99,341 1.879
2020 1,661 87,549 1.897
2021 1,524 96,556 1.578
2022 1,601 96,284 1.663
2023 2,055 95,296 2.156
2024 1,427 97,635 1.462
2025 1,356 96,499 1.405
2026 YTD 498 45,214 1.101

These ratios exceed 1% in several years, but that is not proof Health Canada’s statement is wrong. Plausible explanations include several analyte determinations from one exhibit, a different rolling decade, table-coverage rules, repeated testing or a distinction between “samples” and “analyses.” This is a denominator/unit discrepancy requiring a data dictionary, not evidence of manipulation. Confidence A for the observed arithmetic; D for the explanation.

Verified quantitative concentration data

2024 national powder results

Substance Number of quantitative analyses Mean concentration (% w/w) Public median/min/max/SD/percentiles
Cocaine hydrochloride 732 88.15 Not published
Crack cocaine 42 80.64 Not published
Methamphetamine hydrochloride 222 78.52 Not published
MDMA hydrochloride 31 88.35 Not published
Heroin hydrochloride 11 61.18 Not published
Fentanyl 324 15.05 Not published
Carfentanil 11 0.54 Not published

Source: Health Canada’s downloadable quantitative CSV, retrieved 2026-09-02. Reliability A. The counts are labelled analyses and have not been shown to equal unique exhibits.

National annual trend, powder means (% w/w)

Each cell is mean (number of analyses). 2026 is partial-year and should not be compared as a completed annual estimate.

Year Cocaine HCl Crack cocaine Meth HCl MDMA HCl Heroin HCl Fentanyl Carfentanil
2019 73.19 (870) 69.98 (61) 87.17 (273) 88.57 (7) 49.87 (38) 5.99 (495) 0.36 (66)
2020 73.59 (724) 60.51 (71) 87.71 (115) 86.31 (13) 48.27 (11) 10.55 (632) 2.96 (35)
2021 77.65 (710) 63.63 (94) 95.16 (130) 86.67 (6) 37.72 (14) 12.75 (494) 0.45 (63)
2022 81.60 (680) 73.10 (71) 80.32 (163) 64.88 (16) 57.46 (24) 13.78 (519) 0.50 (46)
2023 85.78 (795) 80.79 (75) 78.79 (249) 87.17 (94) 73.28 (18) 13.87 (625) 0.68 (40)
2024 88.15 (732) 80.64 (42) 78.52 (222) 88.35 (31) 61.18 (11) 15.05 (324) 0.54 (11)
2025 87.33 (712) 73.77 (52) 88.72 (129) 68.55 (44) 72.91 (11) 9.43 (314) 0.78 (22)
2026 YTD 87.23 (264) 81.29 (35) 76.31 (58) 78.00 (13) 8.00 (2) 17.19 (49) 22.22 (33)

The 2026 YTD carfentanil mean of 22.22% is far above previous annual means. It may reflect a small request-driven cluster, outliers, a market change, a method/code/form change or another factor. It should be flagged, not narrated as a settled national trend, until row-level observations and method/selection metadata are obtained. Observed figure A; explanation D.

Requested drugs absent from the located quantitative CSV

No rows were located for hydromorphone, oxycodone, benzodiazepines or xylazine in the current national quantitative CSV. This means only that the located public table contains no such row; it is not evidence that DAS lacks a method or never quantified those substances. Benzodiazepine and xylazine public products provide identification/co-occurrence counts, not concentration distributions. Confidence A for file contents; D for operational capability/frequency.

Tablets versus powders

Powder values are % w/w; tablet values are mg/unit. They are not interchangeable. In 2024, the table reported fentanyl tablets at 3.29 mg/unit (n=7), MDMA tablets at 168.0 mg/unit (n=10), and methamphetamine tablets at 13.73 mg/unit (n=16). A tablet’s mg/unit result cannot be converted to percent without unit mass and formulation information. Confidence A.

Salt/base form caution

The public codes include HCL and FB, but the displayed labels do not provide a complete codebook or conversion rules. The normalized dataset retains the original code and decodes “hydrochloride” only where the public label does so. It does not silently infer that every FB value is a reported free-base equivalent. Confidence A for the data limitation.

The distribution question

The located public quantitative data are insufficient to calculate any requested concentration band—<1%, 1–5%, 5–10%, 10–25%, 25–50%, 50–75%, 75–90%, >90% or >95%—for any drug. A mean and sample count do not identify individual values.

Two fentanyl datasets can each have a 15% mean:

Distribution A has no exhibit below 10% or above 50%; Distribution B has 80 below 10% and 20 above 50%. The same published mean supports both.

Likewise, a cocaine mean of 88.15% is compatible with all samples at 88.15%, or with half at 76.30% and half at 100%. The first distribution has no samples above 90%; the second has half above 90%.

Therefore:

A 2020 peer-reviewed DAS community drug-checking project reported fentanyl concentrations from 1% to 91% w/w, with median 8% in its special-project sample. That establishes measured variability in that scoped project, not the national police-exhibit distribution. Study. Confidence B; generalization ceiling explicit.

Polysubstance and co-occurrence findings

Fentanyl

Health Canada analyzed 77,141 fentanyl exhibits from 2012–2022. In 2022:

Additional identified substances Share of fentanyl exhibits
None 4.4%
1 27.0%
2 33.0%
3 20.7%
4 8.9%
5 3.4%
6 1.7%
7 or more 0.8%

Thus 95.6% had at least one additional identified substance and 69.0% had two or more. Among 2022 fentanyl exhibits, the share with two or more additional substances was reported as 53% in British Columbia, 62% in Alberta and 77% in Ontario. Differences may reflect regional supply, forms, submitting agencies, enforcement patterns, target lists, method sensitivity or combinations of these. Confidence A for the reported figures; D for cause.

Top reported fentanyl co-occurrences over 2012–2022:

Compound Share of fentanyl exhibits
Caffeine 84.8%
Dimethylsulphone 20.6%
Diacetylmorphine (heroin) 16.7%
Etizolam 10.5%
Methamphetamine 7.1%
Cocaine 5.8%
Phenacetin 4.3%
Carfentanil 4.1%
Flualprazolam 3.6%
Diphenhydramine 3.0%

Source: Health Canada fentanyl spotlight. The report groups diverse non-controlled substances together; these percentages do not provide concentration or causal classification. Reliability A.

Xylazine

Among 2,324 xylazine exhibits from 2012–2022, 23 (1.0%) contained no other identified substance; 93% co-occurred with fentanyl. Health Canada reported the following additional-substance counts: none 1.0%, one 1.5%, two 26.4%, three 29.9%, four 22.8%, five 9.5%, six 5.2%, seven 2.4%, eight 0.8%, nine 0.4%, and ten 0.1%. Xylazine spotlight. Confidence A.

The newer 2021–2026 Q1 product reports fentanyl in 74% of xylazine samples, while 28.6% of medetomidine samples also contained xylazine. Differences in date range, denominator and substance definitions must be preserved. Open Government dataset page. Confidence A.

Benzodiazepines

For benzodiazepine samples in the 2017–2026 Q1 product, the leading controlled-substance co-occurrences were fentanyl 49.6%, para-fluorofentanyl 14.8%, methylfentanyl 4.3%, methamphetamine 3.7% and carfentanil 2.7%. In 2025, 28.1% of fentanyl/analogue samples reportedly contained at least one benzodiazepine. These are identities, not concentrations. Open Government dataset page. Confidence A.

Heroin, methamphetamine, cocaine, MDMA and counterfeit tablets

A 2020 CCSA technical report used a DAS-provided sample-level extract covering April 2018–August 2019. The extract contained 167,630 unique DAS samples and listed reported substances by sample but not their quantities, buyer expectation, local context or seizure circumstances.

Index category Samples “Only” index drug/class Any reported other substance Selected co-occurrence finding
Opioid-containing 23,338 31% opioids only 69% included a non-opioid Caffeine 59%; dimethylsulphone 13%
Methamphetamine 37,625 54% only the specific stimulant 46% had something else under report categories Fentanyl/analogue 3% (n=1,021)
Cocaine 38,429 71% cocaine only 29% had something else Fentanyl/analogue 2% (n=931)
MDMA 2,777 83% MDMA only 17% had something else Fentanyl/analogue 1% (n=33)

Source: CCSA technical report. Reliability B: government-funded, DAS-supplied data, transparent limitations; secondary classification. The report does not provide a separate full one/two/three/four/five-plus breakdown for each requested drug, and it cannot distinguish dominant ingredient from trace identification.

No equivalent public count distribution was located for heroin, carfentanil or counterfeit tablets. The announced platform “Co-occurrence Patterns” feature remained marked “coming soon” on the evidence cut-off date. This is a public-data gap, not proof DAS lacks the underlying associations.

Required language discipline

Every same-sample co-occurrence row in this module is classified as:

DETECTED TOGETHER — causal mechanism UNKNOWN

Do not automatically translate it into:

“Contamination” is not a neutral synonym for “a second detected analyte.” Analytically it should identify a proposed mechanism, contextual threshold and evidence basis.

Quantification of mixtures

DAS research provides two important capability findings:

  1. A validated UPLC triple-quadrupole method can quantify cocaine, heroin, methamphetamine and MDMA in one exhibit analysis.
  2. NMRquant was designed to identify and quantify compounds in mixed forensic samples and can quantify controlled substances, diluents and adulterants in a single analysis.

Sources: Health Canada research abstracts, 2020–2021, 2021–2022 abstracts, and the NMRquant methods paper.

These sources establish capability, not the following operational facts:

No verified public Certificate stating a full composition such as “fentanyl X%, bromazolam Y%, caffeine Z%” was located. The correct status is REQUIRES ATIP/DISCLOSURE, not “DAS does not possess the data.”

Why high cocaine/methamphetamine means can coexist with much lower fentanyl means

The figures are chemically and commercially plausible because end-market fentanyl mixtures can deliver pharmacological effect at far lower mass fraction than cocaine or methamphetamine products, while salts, diluents and tablet formulations differ. But the public table cannot apportion the observed difference among:

Thus “selected fentanyl analyses had a much lower mean mass fraction” is established. “The fentanyl supply is more diluted because of deliberate adulteration” is not established from the mean alone. Confidence A for contrast; D for causal decomposition.

Selection-bias assessment

Hypothesis

Published mean DAS concentration figures may be systematically biased because samples selected for quantitative testing are not a random sample of the illicit drug supply.

Classification: SUPPORTED, with limits.

Evidence supporting the classification:

What remains unresolved:

Competing explanations that do not imply wrongdoing:

Explanation Present evidence Status
Evidentiary necessity in a particular prosecution Police-request basis and historical justification rule Supported generally
Resource/capacity allocation Very small subset and service-priority design Plausible; not quantified
Method availability by analyte/form Table covers selected substances/forms Supported generally
Representative surveillance sampling Health Canada disclaims representativeness Unsupported for public table
Focus on large/organized-crime/superlab seizures Institution described security/organized-crime context in OIC case Plausible for some work; quantitative overrepresentation untested
Focus on unusually potent samples No public selection field Unresolved
Deliberate manipulation of published means No evidence located Unsupported/speculative

No causal or accusatory wording should exceed these limits.

Who may submit samples

The Controlled Drugs and Substances Act distinguishes statutory submission to a designated analyst from DAS’s operational client categories. Section 45 permits a peace officer, inspector or prescribed person to submit a substance or sample taken by them. Health Canada separately lists law enforcement, CBSA, CSC and criminal justice representatives as clients.

Submitter Classification Evidentiary basis / limit
RCMP ROUTINE ACCESS Peace officers; named law-enforcement client
Municipal police ROUTINE ACCESS Peace officers; routine client
Provincial police ROUTINE ACCESS Peace officers; routine client
CBSA ROUTINE ACCESS Explicit Health Canada client
Correctional Service Canada ROUTINE ACCESS Explicit client for institutional exhibits
Other federal agencies LIMITED ACCESS Depends on mandate and statutory/person class
Crown / criminal justice representatives LIMITED ACCESS Operational client/liaison described; direct s.45 submitter basis not established
Coroners / medical examiners UNKNOWN No routine DAS route located
Provincial health authorities SPECIAL PROJECT ACCESS Collaborations documented; not general routine entitlement
Supervised consumption sites SPECIAL PROJECT ACCESS Project testing documented
Drug-checking programs SPECIAL PROJECT ACCESS DAS-supported projects documented
Festivals/event drug checking SPECIAL PROJECT ACCESS Health Canada evaluation describes activity
Academic researchers SPECIAL PROJECT ACCESS Research collaboration possible; direct routine route not established
Ordinary public NO APPARENT ACCESS Not a named client or established s.45 class

Authorities: CDSA s.45, DAS service page, and CDSS evaluation. Confidence A for statutory text and named clients; B/D for limited and special categories.

Public-health submissions could affect aggregate patterns if included, because their selection mechanisms differ from police exhibits. The current public quantitative file has no submitter/project field, so material effect cannot be measured. Plausible but unresolved — D.

Certificates of Analyst and underlying records

Health Canada says a Certificate of Analyst is produced for each analyzed sample. Under CDSA ss.51–52, an analyst’s certificate/report may be admissible as proof of its statements, subject to statutory procedure; Criminal Code s.729 addresses notice and provision of a copy when such a certificate/report is used.

Located examples

Example Substance statements located Concentration shown in accessible source? Evidentiary limit
Public 2022 Gatineau scan Cocaine No Purported certificate hosted by a user; authenticity/provenance unverified (D)
R. v. Auclair, 2023 ONSC 6590 Fentanyl and caffeine Not stated in reasons Judicial reasons summarize certificate; court discussed why quantitation is not commonly requested (A)
R. v. Folk, 2025 ONSC 4243 Cocaine, fentanyl, phenacetin and caffeine Not stated in reasons Judicial reasons show multi-compound identity reporting, not complete composition (A)

Links: Auclair, Folk, and unverified scan.

Fields visible in the unverified scan include laboratory/location, analyst, source police service, delivery/possession date, seal/file identifiers, a sealed-package statement, sampling statement and controlled-substance/schedule finding. It did not visibly report concentration, method, uncertainty or a complete composition. One scan cannot define all certificate formats.

Disclosure ceiling

Current and historical manuals, SOPs and methods inventory

Record Located status Date/version Access note
Client Manual for Exhibit Submission & Analysis Requests Current document exists Current Health Canada says available on request
Client Manual Catalogue record September 2013, 54 pages, ISBN 978-1-100-22552-4 PDF removed from publications.gc.ca at department request; original collection URL no longer available
Client Manual Catalogue record September 2016, 43 pages, ISBN 978-0-660-05417-9 PDF removed at department request
Client Manual Catalogue record March 2019, 43 pages, ISBN 978-0-660-29608-1 PDF removed at department request
Training Manual Catalogue/current service reference 2013 catalogue; current version available on request Full historical/current text not retrieved
Clandestine Laboratory Investigation: Guidelines for Law Enforcement Agencies Current document exists Current Available on request
Client Portal User Manual Current document exists Current Available on request
DAS Quality Manual Official holdings inventory lists it Current/historical versions unknown Requires ATIP; some operational content may be exempt
SOP master index Not located publicly Unknown ATIP target
Method-validation publications Several located 2020–2022 abstracts/papers Capability evidence, not complete SOP set

Catalogue links: 2013, 2016, 2019. The fact that PDFs were removed is documented; motive beyond the catalogue notation is unknown. It must not be rewritten as “concealment.” Confidence A for catalogue status; E for unproven motive.

Public access inventory

Product Public? Observation level Main limit
Analyzed Drug Report Yes Aggregated counts/trends and national quant means No anonymous exhibit records
Direct downloadable CSVs Yes Aggregated substance/year/quarter/province tables No documented exhibit ID or selection reason
Drug Trends Yes Aggregated time trends Submission/testing changes affect inference
Drug Notification Map Yes Selected alerts by region/time Notification criteria; not a prevalence map
Purity/quantitative table Yes National mean/count by selected drug, year/quarter and form No distribution/province/agency
Co-occurrence spotlight reports Yes Aggregate same-sample identifications No quantities/intent/cause
“Co-occurrence Patterns” platform feature Not yet on cut-off date Announced Marked coming soon
Scientific publications/method papers Yes, selected Methods/special projects Not a full operational-method registry
Searchable exhibit-level DAS database Not located — Unknown whether planned
Documented public API Not located — Direct CSV endpoints are not an exhibit-level API

Platform: Analyzed Drug Report, Drug Trends, Drug Notification Map, publications.

Contradictions and discrepancies register

  1. One-percent narrative versus 1.4–2.2 determinations per 100 samples. Possible unit/time/coverage mismatch; unresolved until Health Canada supplies the data dictionary. Do not call this falsification. A/D.
  2. “All substances” wording in the 2020 CCSA report versus current non-controlled reporting limitation. “All” may mean all reported identifications in the supplied extract, not complete chemical composition; methods/scope may also have changed. B/D.
  3. 2026 YTD carfentanil mean. 22.22% (n=33) is discontinuous with prior annual means. Small selected subset and other innocent explanations remain open. A/D.
  4. Current manuals available on request versus removed historical PDFs. This establishes an access barrier/history, not intent. A/E.
  5. Technical multi-analyte capability versus sparse public composition reporting. Capability does not imply routine performance, LIMS retention or certificate disclosure. B/D.

Alternative explanations matrix

Observation Competing explanations that remain live
Increasing number of co-detected substances Market change; target-list expansion; sensitivity improvement; changed submission mix; changed reporting rule
Fentanyl mean lower than stimulant means Pharmacological potency/formulation; market practice; salt/base conventions; selection by case/drug; method/reporting differences
Provincial co-occurrence differences Genuine regional supply; enforcement priorities; public-health submissions; forms; method/lab changes; small cells
High annual mean Many consistently high results; bimodal distribution; a few high outliers; case clustering; seizure-size selection
Compound appears in same sample Intentional formulation; accidental mixing; synthesis carryover; cross-contamination; trace analytical carryover; unknown
Non-controlled compound absent from public data Truly absent; not targeted; below threshold; detected but not systematically recorded/reported; excluded from publication
Quantitative result requested Evidentiary need; policy/charge requirement; large seizure; special research; unusual potency; routine method opportunity

Unresolved questions and evidence needed

The 40 staged question cards are in data/question_cards.jsonl. The highest-value unresolved issues are:

The accompanying ATIP draft requests these records in anonymized machine-readable form and asks for field-level severance instead of case identifiers.

Suggested court-record searches

  1. Search CanLII and provincial repositories for combinations of "Certificate of Analyst" AND (purity OR concentration OR quantitative OR chromatogram OR spectrum OR LIMS OR bench notes).
  2. Search for fentanyl AND caffeine AND "Certificate of Analyst", carfentanil AND concentration, and bromazolam AND certificate.
  3. Prioritize cases where purity affected sentencing, trafficking value, possession for the purpose, expert opinion, representative sampling or hotspot arguments.
  4. Obtain docket exhibits/transcripts for Auclair and Folk; judicial summaries alone are not certificate images.
  5. Seek disclosure indices before full files to identify whether bench notes, spectra, validation and chain-of-custody records were produced.
  6. Record certificate version, lab, date, field presence/absence and whether the court relied on identity, concentration or both.
  7. Do not treat a judgment’s summary of expert evidence as the laboratory record itself; preserve the layer court summary of certificate.

ATIP and disclosure strategy

The proposed request asks for a stable anonymous exhibit ID, every detected/reported substance, all quantitative values/units, methods, selection/request fields, geography, form/weight, LOD/LOQ, uncertainty, reanalysis linkage and project type, while expressly inviting removal of police file numbers and personal identifiers.

It also seeks manuals, SOP indexes, the Quality Manual, LIMS codebooks, retention schedules, quantitation-selection policies and guidance on which adulterants/excipients are recorded.

The 2026 Information Commissioner decision is important context. In Health Canada (Re), 2026 OIC 14, Health Canada had withheld DAS-related records under law-enforcement, advice and testing-procedure exemptions. The Commissioner found the complaint well founded, held that Health Canada had not justified many redactions or full-page withholding, and ordered substantial severed disclosure. The decision also accepted that some testing details could properly remain exempt. It supports targeted, severable requests; it does not establish that an anonymized LIMS dataset has already been released. Confidence A.

These are flags, not automatic duplicates:

Finding Target
Selected fentanyl means and distribution limits Fentanyl Science Deck
Fentanyl 95.6% additional-substance finding Fentanyl Science Deck
“Detected together” language guardrail Fentanyl Language Deck
Certificate scope and disclosure Fentanyl Legal Deck
Request-driven selection and bias Law Enforcement Deck
Public-health/festival projects Public Institutions Deck
Multi-analyte capability and method evolution Research & Science Deck
Co-detection versus lacing/contamination Contaminated Drug Supply / Laced-with-Fentanyl registry

Before import, recover ED-P25QE and ED-CSM-001, deduplicate by claim/source family, preserve existing IDs and append new evidence-assessment versions. No public card or adverse inference should be created automatically.

Source inventory and reliability

The machine-readable inventory contains 27 sources in data/sources.jsonl, with publication/access dates, URLs, local-copy paths where available, scope notes and A–E reliability ratings.

Source families include:

No search-engine snippet is treated as evidence. No inaccessible historical manual is treated as if its contents were reviewed. “Not located publicly” is not converted into “does not exist” or “is concealed.”

Final answer to the central question

When Canadian authorities describe the illicit supply as variable or containing multiple drugs, DAS provides strong evidence for identified substances in the submitted exhibits it actually tested, and special studies demonstrate large concentration variability in scoped samples. For fentanyl, the 2022 same-exhibit evidence strongly supports widespread co-occurrence with at least one additional identified substance.

However, the routine public record is primarily qualitative; non-controlled compounds are not systematically tested/reported; concentration testing is performed on a small, request-driven subset; and the public concentration table provides means rather than distributions. Consequently, public DAS data alone cannot establish the proportion of the entire illicit supply that is dilute, nearly pure, deliberately “laced,” accidentally contaminated or unusually potent. Nor can it determine how selection affects a drug’s published mean.

The evidence therefore permits four bounded statements:

  1. Identity: many submitted exhibits contain the substances DAS reports identifying. A.
  2. Co-occurrence: many fentanyl and xylazine exhibits contain additional identified substances. A.
  3. Selected concentration: specified, requested quantitative analyses have the reported national means and show change over time. A.
  4. Population/causal inference: full market distributions, intentional lacing, mechanism of contamination and selection-bias magnitude remain unresolved without anonymous row-level LIMS/quantitative records, selection fields and method history. D / REQUIRES ATIP OR DISCLOSURE.

That boundary—not a claim of wrongdoing—is the module’s principal finding.


Artifact guide